Pack
Packhouse inspections in orchard language
SmartCrop records defects, starch, sugar and firmness one sample at a time, with the FTA penetrometer wired into the browser and a report you can print.
Two packhouse inspections
Defect Analysis and Room Sample, one wizard
Defect Analysis covers fruit off the packing line. Room Sample covers numbered samples pulled from cold storage. Both share grower, lot, ranch, block, variety and crop year.
- Defect Analysis with picked and packed dates
- Room Samples numbered by room
- Review every step before you submit
- HoneycrispSep 10 · Ridge Road · Lot 2401Good Fruit
- HoneycrispSep 9 · East Slope · Lot 2404Bad Fruit
- GalaSep 9 · Bench Ranch · Lot 2402Good Fruit
- FujiSep 8 · Riverbend · Lot 2403Good Fruit
- Cosmic CrispSep 6 · Ridge Road · Lot 2401Good Fruit
- Granny SmithSep 5 · East Slope · Lot 2405Good Fruit
- Basic info
- Defects
- Starch
- Pressure
- Confirm
Defect counting
Defects counted per sample, in your vocabulary
Sample size, clean samples and samples affected per defect type, with percentages as you type.
- Apple defect types seeded from day one, bruise to bitterpit
- Rename, retire or add types per company
- Total defects and percent affected, per defect and overall
- Bruise4 of 100 samples4.0%
- Stem Puncture3 of 100 samples3.0%
- Russet2 of 100 samples2.0%
- Bitterpit1 of 100 samples1.0%
Starch and sugar
Maturity statistics as readings come in
Starch index and sugar per sample, with min, max, average, standard deviation and range calculated instantly.
- UNEVEN MATURITY flag above a 2.5 starch range
- Starch Scan reads the starch index from iodine-test photos
- Photo kept on the inspection as evidence
- Fruit 1 · Starch 3.50Sugar 13.50
- Fruit 2 · Starch 4.40Sugar 14.10
- Fruit 3 · Starch 3.00Sugar 12.60
- Fruit 4 · Starch 3.60Sugar 13.40
- Fruit 5 · Starch 3.80Sugar 13.00
- Fruit 6 · Starch 3.90Sugar 13.80
- Fruit 7 · Starch 3.70Sugar 12.70
Pressure
Firmness from the FTA, straight into the form
Up to three lbf readings per sample, typed, captured from the tester or pasted from the Excel template.
- USB capture in Chrome or Edge, no software
- Bluetooth capture in SmartCrop QC
- Press the button, hear the chime, reading lands
- Fruit 1Pressure 1 · 2 · 316.3 · 16.0 · 15.8
- Fruit 2Pressure 1 · 2 · 316.9 · 16.4 · 15.7
- Fruit 3Pressure 1 · 2 · 315.5 · 16.8 · 16.1
- Fruit 4Pressure 1 · 2 · 316.6 · 15.9 · 16.4
- Fruit 5Pressure 1 · 2 · 316.2 · 17.0 · 15.6
- Fruit 6Pressure 1 · 2 · 315.9 · 16.3 · 16.7
Verdict and records
GOOD FRUIT or BAD FRUIT, evidence attached
The inspector makes the call. The record keeps the photos, the lot and the numbers.
- Tagged defect, watercore, internal and starch photos
- Lot number filled from the grower and kept on the record
- Print the QC Inspection Report to PDF
- Filter, sort and export lists to CSV
- Clean Samplesof 100 sampled58
- Pressure±1.24 std · n=814.6 lbf
- Avg Starchtarget 3 – 55.1
- Avg Sugartarget 12 – 1612.4
- GrowerHighline Orchards LLC
- Ranch · BlockEast Slope · ES-1
Pass rate
Pass rate by ranch, week and season
A QC dashboard on the web, pass-rate reports in SmartCrop QC, and a daily pass rate on the executive dashboard.
- Counts by type, variety and warehouse
- Weekly, monthly and seasonal trends
- Top defects and per-ranch breakdown
- Defect Analysis14 inspections93%
- Receiving14 inspections86%
- Room Sample14 inspections96%
- Ridge RoadBy ranch · 11 inspections94%
- East SlopeBy ranch · 8 inspections79%
- BruiseTop defect · samples affected38
Setup and permissions
Configured for your packhouse
Pick lists are yours. QC staff get only the access they need, on web and in the app.
- Your own packing lines, sample locations and room numbers
- Granular View, Create, Edit and Delete permissions
- Same login and permissions on the web and in SmartCrop QC
On the roadmap: inspections tied to lots as they move to Sell & Ship.
Answers
Common questions
Something not covered here? Write to hello@smartcrop.com and we will reply within two business days.
Which pressure tester works with SmartCrop?
The FTA Fruit Texture Analyser, over USB in Chrome or Edge on the web, or a Bluetooth serial adapter in SmartCrop QC. Readings are recorded in lbf.
Can inspections be recorded on a phone or tablet?
Yes. SmartCrop QC on iOS and Android records all three inspection types, runs Starch Scan, captures FTA readings over Bluetooth and prints PDF reports, with the same login and permissions as the web.
How does Starch Scan work?
Starch Scan reads the starch index from iodine-stained cross-sections and fills the table for you. The inspector reviews every value, and the photo stays on the record.
Where does receiving inspection live?
Receiving inspections, by ticket number and bin count, sit in the Receive & Store pillar. They share the same defect, starch and pressure steps.
See an inspection from sample to report
A Defect Analysis run end to end, from the sample on the line to the printed report.